New generation of laser light source. Integrated design more stable, simple, and durable. Available models:
CSLO (NIR + RF + MCOLOR)
CRO (AF+NIR + RF+ FFA + MCOLOR)
CRO PLUS (FFA + ICGA + AF + RF + NIR + MCOLOR)
Microclear HFC
Microclear HFC is designed to make it easy to reliably capture good retina photos even by staff with a simple training.
The Android Operating System on the 3.9 display makes it easy and intuitive to perform many standard operations such as connecting to WiFi, sharing images and printing.
No need to dilate the pupil, shooting at 2.5mm allows a higher success rate of gradable photos compared to the industry average.
Automatic features such as intelligent image recognition, autofocus and automatic detection of fundus image assist the operator in taking the best shot possible.
Using HFC is comfortable for the patient also: there is no continuous light on the eye, the operation is quick, the hand held operation enables bedside examination of patients unable to sit up.
For even faster and easier image capture you can apply the mounted base and increase stability.
Ophthalmologist's workplace
The ophthalmologist's workplace (ophthalmological combine) is designed to accommodate special ophthalmological devices and conduct patient examinations. The workplace consists of a tabletop, a stand and a patient chair, as well as brackets for attaching a phoropter and a sign projector.
Slit Lamp VSL-550
Supreme optical design for VSL-550 provides a clear observation view for clinicians to examine patient’s eye. The details of the eye can be easily recognized from the eye piece.
High-illuminance LED We applied high-illuminance LED to deliver almost same illumination effect as halogen bulb. The image observed by clinicians are close to the natural color/
Excellent Mechanics The finely calibrated mechanics enable precise movement of the slit lamp. Clinicians can operate the device freely upon their needs
Instrument Table VT-18H
Specification
VT-18H
Table Top Size
92X50 cm
Table Elevator Height
70~90 cm
Wheelchair Accessibility
Yes
Lifting Capacity
50 Kgs
Input
AC 110-220 ± 10%,50/60 HZ
Fuse
5A/250VA
Weight
60 Kgs
Portable slit lamp SL1911D
High Quality Optics VisuScience portable slit lamp is made with high quality optical glasses. The lenses are with multiple coating. As a result, the slit lamp delivers sharp slit enable clinicians to see the lens clearly.
LED Illumination VisuScience portable slit lamp uses LED bulb for illumination. The color temperature of the bulb is similar to halogen bulb. It has a life span of 20,000 hours. It won’t generate too much heat.
Rechargeable Li-ion Battery A customized rechargeable Li-ion battery is applied in VisuScience portable slit lamp. After fully charged, the slit lamp can be used for 6 hours continuously. The clinician can do recharge by putting whole device on recharging dock or take the battery out to recharge separately.
1X1mm Square Aperture Apart from common apertures other slit lamp offers, VisuScience portable slit lamp provides 1X1 mm square aperture for clinicians to assess anterior chamber flare.
Perimeter
Standard Full Field White on White Perimetry The IFA series visual field analyzer offer a wide range of test patterns and strategies, including T30-2, T24-2, T10-2 for glaucoma diagnosis and T-Macula for macula function assessment. In addition, special test patterns like driver feasibility, monocular/binocular social security disability are also included. For better detection of visual field loss caused by early stage glaucoma, points of T30-2 and T24-2 are cautiously configured on the most sensitive position of retinal nerve fiber bundle.
Regionally Condensed Stimuli Test
VisuScience IFA950/960 perimeter/visual field analyzer offer a unique function called regionally condensed stimuli test. It enables doctors to add more stimuli around each standard stimulus to increase the accuracy in detecting vision loss. As can be seen from the following test screenshot, the test is divided into 76 grids. Users can add more stimuli in each grid with density of Interval 1。/2。/3。options.
Regionally Condensed Stimuli Test Application 1
In the superior paracentral visual field, the RCS report clearly demarcates a circumscribed paracentral small retinal nerve fiber–related scotoma corresponding to a previous splinter hemorrhage shown in the (inset) optic disc photograph (the optic disc is turned upside down).
Regionally Condensed Stimuli Test Application 2 For confirmed glaucoma patients, doctor need to see the visual field status both for macula and peripheral area to track the progression. Conventionally, this was done through one T30-2 test plus one T10-2 test. With RCS, this can be done with only one test of T30-2 + some densified area.
MeiboVue
Quick Meibomian Gland Check at 30 Seconds
MeiboVue can capture Meibomian glands images within 30 seconds for one eyelid. The video shows how an asymptomatic MGD case is spotted by MeiboVue.
Technician Friendly Use
Thanks to the high image quality offered by MeiboVue, technician can easily see the glands clearly in the preview mode. With good preview live image, technician can easily focus and capture good meibomian gland image for doctors’ further review.
Quick Upload to EMR
Connect smartphone and PC with a cable.
Copy images from phone to PC folder.
Upload from PC to EMR.
QuikVuePlus
Quick Eye Image Documentation
QuikVuePlus is an eye imaging adaptor that can be attached to smartphone or tablets. It enables practitioners to quickly capture high quality anterior segment images. It is a fantastic tool for optometry and ophthalmology documentation and patient education. It provides 10x magnification which meets the basic eye examination demand for optometrists, general practitioners, pediatricians, veterinarians, etc.
Color and Fluorescein Imaging QuikVue Plus provides both white and blue illumination respectively. The white LED projects warm white light which is similar to slit lamp’s halogen illumination. There are two levels of white illumination available to meet different brightness demand during examination. The blue illumination can be used to capture fluorescein images to assist diagnosis with corneal staining and contact lens fitting, etc.
Smartphone Compatibility Thanks to the air cushion design, QuikVue Plus is able to attach on most of the phones in the market firmly. Practitioners need to align QuikVue Plus lens with smartphone’s main camera. The requirements for the main camera location is that it needs to be within 5 cm distance from the edge of phone.
Working Application QuikVue plus can work with smartphone default camera app or VisuScience developed VisuDoc ophthalmic case management app. VisuDoc can be downloaded from both App store and Google play store.
Power Management QuikVue Plus applies mini Li-ion rechargeable battery. It can be recharged through a Type C cable. There is one light indicator next to the Type C charging port. When the power recharging is finished, the indicator light will turn from blue to green.
The switch button has blue light on when working normally. If the power is low, the light will flicker as a reminder for recharge.
IFlo
Effective Warm Compress For highest level temperature option, the heating temperate can steadily increase to 42 degrees which can melt the thick oil inside meibomian glands.
Quickly Feel the Heat The user can feel the heat within 1 minute from the eye mask. The heat is precisely and evenly distributed in eyelids area.
3 Heating Options The newly designed control cable has below features:
Overvoltage protection to ensure safety use
Intuitive temperature icons for easy understanding
Larger control button for easier press
Passed ROHS and FCC tests
Hard Eye Blink Reminder The control rings a long beep at 8th and 10th minute to remind users to hard blink their eyes to squeeze the softened oil out during heating. At 12th minute, the control rings short beep for 3 times to indicate the end of a heating session.
Better Fit at Eyelid Area
FlexStrip™ is an adjustable string positioned in the nose bridge area of the iFlo eye mask. User can adjust the eye mask fit by pressing the string inside eye mask. Better fit provides better heating effect at the eye lid area.
Made with Recycled Fabric iFlo dry eye mask is made with recycled fabrics. These high-quality fabrics are transformed from plastic waste. This sustainable approach reduces landfill waste, conserves natural resources, and minimizes the environmental footprint of production. Especially, 3M Thinsulate material is applied inside eye mask. It is super light and soft which create a comfortable wearing experience to the user.
Overheating Alert and Stop Heating Safety is utmost important for heating eye masks. iFlo has applied smart chip to detect overheating. When the chip detects abnormal heating situation, the control cable will cut off electricity supply to eye mask. The red light will flicker indicating the malfunction.
As a result, the eye mask will stop heating.
Contact us
Your experience on this site will be improved by allowing cookies.